Frequency coverage: |
amateur bands 1.8 – 29.7 MHz including WARC |
Power output: |
2500 W in SSB and CW
2000 W in RTTY, AM and FM |
Driver Power: |
60 to 80 W for full Output Power |
Input impedance: |
50 Ohm VSWR < 1.5 : 1 |
Output amplification: |
17 dB |
Output impedance: |
50 Ohm unbalanced |
Maximum output SWR: |
2:1 |
SWR protection: |
automatic switching to STBY , when reflected power is 350W or higher |
Intermodulation distortion: |
32 dB below nominal output |
Suppression of harmonics: |
< -50 dBc |
Tube: |
GU84b Ceramic tetrode |
Cooler: |
Centrifugal blower + axial blower |
Power supply: |
2 x 230 V - 50 Hz one or two phases |
Transformers: |
2 pcs of toroidal transformer 2.0 kVA |
Protection circuits: |
- SWR too high |
|
- Anode current too high |
|
- Screen current too high |
|
- Grid current too high |
|
- Mistuning of power amplifier |
|
- Soft start for protecting your fuses |
|
- “switch –on blocking “ at opened amplifier |
Bar graph indications: |
- Power output – bargraph 50 LED |
|
- Reflected power – bargraph 20 LED |
|
- Current at screen ( Ig2 – bar graph 10 LED ) |
|
- Anode voltage, anode current, tuning – bargraph 30 LED |
LED indicators: |
- current at control grid ( Ig1 – 2 LED ) |
|
- WAIT – preheating of tube (180 sec ) |
|
- STBY– standby |
|
- OPR – operating condition |
|
- FAULT – failure, switching off for abt. 4 sec |
|
- Inhibit – operating condition |
|
- ANT 1 - which ANT is use |
|
- ANT 2 – which ANT is use |
|
- UP – DWN - listing in menu |
|
- MAN - manual operating |
|
- AUTO - automatic operating |
|
- TUNE - tuning |
|
- ANT - ANT selection |
Parameters: |
485 x 200 x 455mm (width x height x depth) |
Weight: |
40 kg |